Background
A gold mine operating a conventional carbon-in-leach (CIL) gold extraction process had significant scaling challenges, primarily due to high calcium levels and elevated pH after cyanidation. The presence of scale-forming compounds, particularly calcite, posed operational risks including:
- Reduced carbon absorption efficiency in the CIL process due to carbonate scale deposition on activated carbon.
- Scale formation in heat exchangers, process water lines, and motor coolers, compromising equipment efficiency and increasing maintenance costs.
A preliminary qualitative XRD analysis of ore deposits indicated the presence of calcite (dominant), bassanite (minor), and trace amounts of quartz, dolomite, and zeolite. Mathematical modelling confirmed a high scaling potential under current process conditions.
WTS solution
Our team adopted a holistic, phased approach to scale inhibition:
WTS key solutions
- Site Assessment: Conducted a detailed inspection of process systems to identify critical scaling locations.
- Monitoring Setup: Installed scale coupons at strategic points for baseline measurement of scale formation.
- Chemical Integration: Introduced WTS 4-123 antiscalant into key water circuits.
- Data Collection and KPI Establishment: Collected system performance data to define key performance indicators (KPIs) including scale control, chemical consumption, inventory management, and operator compliance.
- Training & Service Support: Provided hands-on training to site personnel, establish monitoring regimes, and offer continuous service support during start-up and long-term operations.
The WTS multicomponent antiscalant WTS 4-123 is a high-performance liquid formulation containing a unique group of polymer building blocks developed by WTS. This makes it particularly effective for controlling the precipitation of calcium-based scale in alkaline, calcium-rich mining circuits. The combined scale inhibiting and dispersing properties prevent the formation of new deposits and slowly remove existing deposits from the system.
![]() |
![]() |
| Untreated process water Before WTS 4-123 antiscalant |
Treated process water After WTS 4-123 antiscalant |
Red = scaling, Pink & Yellow = potential scaling, Blue = non-scaling
Results and Benefits
- Effective scale prevention: Achieved across critical systems.
- Reduced maintenance and downtime: Minimised frequency of maintenance and downtime due to scale-related blockages.
- Maintain process efficiency: Sustained carbon absorption efficiency in CIL operations.
- Safe and compliant chemical use: Ensured environmentally compliant application with no adverse effects on process water quality.
- Cost effective operation: Delivered predictable chemical consumption and minimal inventory disruptions.